LRS-50-75-100-200 Enclosed Type Switching Power Supply
- Features short-circuit, overload, and overvoltage protection.
- High resistance to shock and vibration
- Greater stability during long-term operation
- Operating temperature range: -40°C to +85°C
- Cooled via natural air convection.
Product Overview & Applications:
The LSR series of enclosed power supplies is a high-performance, highly reliable power solution designed to power industrial automation, control systems, and various types of equipment. Featuring a wide input voltage range, the series adapts to diverse power environments, ensuring stable equipment operation under various conditions.
Additionally, the series offers a range of output power specifications to meet diverse application needs, making it an ideal power solution for the industrial sector.
Technical Parameters
LRS-50 Learn more about this product.
Product Specifications | ||||
| Model Number | LRS-50-5 | LRS-50-12 | LRS-50-24 | LRS-50-48 |
| DC Output Voltage | 5V | 12V | 24V | 48V |
| DC Output Current | 10A | 4.1A | 2.2A | 1A |
| Rated Power | 50W | 50W | 50W | 50W |
| Ripple & Noise | 79mVp-p | 120mVp-p | 160mVp-p | 200mVp-p |
| Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load Regulation | ±1.0% | ±0.5% | ±0.5% | ±0.5% |
| Efficiency | 81% | 85% | 88% | 89% |
| DC Voltage Adjustment Range | ±10% | |||
| AC Input Voltage Range | 85~264VAC / 120~360VDC | |||
| Inrush Current | Cold Start: 45A / 230VAC | |||
| Overload Protection | 105%~130%, Output Shutdown, Auto Recovery | |||
| Overvoltage Protection | 5.9~7.3V | 13.8~16.2V | 28.8~33.6V | 55.2~64.8V |
| Overvoltage Protection Mode | Output Shutdown, Restart Required | |||
| Setup/Rise/Hold Time | 1000ms,30ms/230VAC; 2000ms,30ms/115VAC | |||
| Withstand Voltage | I/P-O/P:2.5KVAC; I/P-FG:1.5KVAC; O/P-FG:0.5KVAC (1 Minute) | |||
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:500VDC/100MΩ | |||
| Operating Temperature & Humidity | -10°C~+60°C,20%~90%RH | |||
| Safety Standard | GB4943 | |||
| EMC Standard | GB9254, EN55022 Class A | |||
LRS-75 Learn more about this product.
Product Specifications | ||||
| Model Number | LRS-75-5 | LRS-75-12 | LRS-75-24 | LRS-75-48 |
| DC Output Voltage | 5V | 12V | 24V | 48V |
| DC Output Current | 12A | 6A | 3.2A | 1.6A |
| Rated Power | 60W | 72W | 76.8W | 76.8W |
| Ripple & Noise | 100mVp-p | 150mVp-p | 200mVp-p | 200mVp-p |
| Current Range | 0~12A | 0~6A | 0~3.2A | 0~1.6A |
| Voltage Adjustment Range | 4.5~5.5V | 10.2~13.8V | 21.6~28.8V | 43.2~52.8V |
| Voltage Accuracy | ±2.0% | ±1.0% | ±1.0% | ±1.0% |
| Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load Regulation | ±2.0% | ±1.0% | ±0.5% | ±0.5% |
| Setup Time / Rise Time | 500ms,30ms@230VAC; 1000ms,30ms@115VAC (Full Load) | |||
| Hold-up Time (Typ.) | 370ms@230VAC; 10ms@115VAC (Full Load) | |||
| Input Voltage Range | 85~264VAC / 120~370VDC | |||
| Frequency Range | 47~63Hz | |||
| Efficiency | 82% | 87% | 89% | 90% |
| Input Current | 1.5A/115VAC; 0.85A/230VAC | |||
| Leakage Current | <1.0mA/240VAC | |||
| Overload Protection | 110%~150%, Hiccup Mode, Auto Recovery | |||
| Overvoltage Protection | 5.7~6.8V | 14~17V | 28~33V | 55~65V |
| Overvoltage Protection Mode | Output Shutdown, Auto Recovery | |||
| Operating Temperature | -30°C~+70°C | |||
| Working Humidity | 20%~90%RH, Non-condensing | |||
| Storage Temperature & Humidity | -40°C~+85°C,10%~95%RH | |||
| Vibration Resistance | 10~500Hz, 5G, 10min/Cycle, XYZ Each 60min | |||
| Withstand Voltage | I/P-O/P:1.5KVAC; I/P-FG:1.5KVAC; O/P-FG:0.5KVAC | |||
| Insulation Resistance | 100MΩ, 500VDC, 25°C, 70%RH | |||
| EMC Emission | EN55032 Class A | |||
| EMC Immunity | EN61000-4-2 | |||
| Safety Standard | GB4943 | |||
LRS-100 Learn more about this product.
Product Specifications | ||||
| Model Number | LRS-100-5 | LRS-100-12 | LRS-100-24 | LRS-100-48 |
| DC Output Voltage | 5V | 12V | 24V | 48V |
| DC Output Current | 18A | 8.3A | 4.1A | 2A |
| Rated Power | 100W | 100W | 100W | 100W |
| Ripple & Noise | 100mVp-p | 120mVp-p | 150mVp-p | 150mVp-p |
| Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load Regulation | ±1.0% | ±0.5% | ±0.5% | ±0.5% |
| Efficiency | 85% | 88% | 90% | 91% |
| DC Voltage Adjustment Range | ±10% | |||
| AC Input Voltage Range | 85~264VAC / 120~360VDC | |||
| Inrush Current | Cold Start: 50A/230VAC | |||
| Overload Protection | 105%~130%, Output Shutdown, Auto Recovery | |||
| Overvoltage Protection | 115%~145% of Rated Output Voltage | |||
| Overvoltage Protection Mode | Output Shutdown, Restart Required | |||
| Setup / Rise Time | 500ms,55ms@230VAC; 500ms,30ms@115VAC | |||
| Withstand Voltage | I/P-O/P:4KVAC; I/P-FG:2KVAC; O/P-FG:1.25KVAC (1 Minute) | |||
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:500VDC/100MΩ | |||
| Operating Temperature & Humidity | -10°C~+60°C,20%~90%RH | |||
| Working Humidity | 20%~90%RH, Non-condensing | |||
| Safety Standard | GB4943 | |||
| EMC Standard | GB9254, EN55022 Class A | |||
LRS-200 Learn more about this product.
Product Specifications | ||||
| Model Number | LRS-200-12 | LRS-200-24 | LRS-200-36 | LRS-200-48 |
| DC Output Voltage | 12V | 24V | 36V | 48V |
| DC Output Current | 17A | 8.8A | 5.9A | 4.4A |
| Rated Power | 200W | 200W | 200W | 200W |
| Ripple & Noise | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p |
| Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load Regulation | ±1.0% | ±0.5% | ±0.5% | ±0.5% |
| Efficiency | 87% | 88% | 90% | 91% |
| DC Voltage Adjustment Range | ±10% | |||
| AC Input Voltage Range | 90~132VAC / 180~264VAC (Selectable by Switch) | |||
| AC Inrush Current | Cold Start: 60A/110VAC; 60A/230VAC | |||
| Overload Protection | 105%~130%, Output Shutdown, Auto Recovery | |||
| Overvoltage Protection | 115%~145% of Rated Output Voltage | |||
| Overvoltage Protection Mode | Output Shutdown, Restart Required | |||
| Setup / Rise Time | 1300ms,50ms@230VAC; 1300ms,50ms@115VAC | |||
| Withstand Voltage | I/P-O/P:3KVAC; I/P-FG:2KVAC; O/P-FG:0.5KVAC | |||
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:500VDC/100MΩ | |||
| Operating Temperature & Humidity | -10°C~+60°C,20%~90%RH | |||
| Safety Standard | GB4943 | |||
| EMC Standard | GB9254, EN55022 Class A | |||
Get an Instant Quote for Your Latest Project
From precise Temperature Controllers and Thermocouples to Solid State Relays, Switching Power Supplies, Contactors, and Circuit Breakers—LCTC provides a complete, reliable ecosystem for your control cabinets. Submit your bill of materials (BOM) today for an integrated, volume-discounted quote within 24 hours.