LPV-25 Waterproof Power Supply
- Supports , 12V,15V, 24V applications with flexible voltage settings.
- Built-in constant current limiting circuit.
- Efficiency reaches up to 94%
- Maximum output power of 650W
- The operating temperature range extends up to -30°C to 70°C.
Product Overview & Applications:
The LCTC waterproof switching power supply is specifically designed for outdoor equipment and applications in harsh industrial environments.
If standard switching power supplies are used outdoors, they are easily affected by rain, sand, and dust; in industrial environments, metal particles and construction dust can also easily clog the ventilation openings.
LCTC waterproof power supplies ensure reliable operation outdoors during rainy seasons and in high-humidity environments; they can withstand prolonged exposure to weather elements without being affected by seasonal temperature fluctuations. It can operate in environments with temperatures ranging from -30°C to 70°C, minimizing downtime and maintenance costs while ensuring stable and continuous power supply.
Technical Parameters
Product Specifications | |||||
| Model number | LPV-25-12 | LPV-25-15 | LPV-25-24 | LPV-25-27 | |
| Output | DC Voltage | 12V | 15V | 24V | 27V |
| Rated Current | 2A | 1.6A | 1A | 0.9A | |
| Current Range | 0~2A | 0~1.6A | 0~1A | 0~0.9A | |
| Rated Power | 24W | 24W | 24W | 24.3W | |
| Ripple & Noise | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
| Voltage Accuracy | ±3.0% | ±2.0% | ±1.0% | ±1.0% | |
| Linear Adjustment Rate | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
| Load Regulation Rate | ±2.0% | ±1.0% | ±0.5% | ±0.5% | |
| Start-up, Rise Time | 500ms, 80ms/230VAC (Full Load) | ||||
| Hold Time (Typ.) | 16ms/230VAC (Full Load) | ||||
| Input | Voltage Range | 95~264VAC / 135~373VDC | |||
| Frequency Range | 47~63Hz | ||||
| Efficiency (Typ.) | 83.50% | 83.50% | 84.50% | 84.50% | |
| AC Input Current | 0.5A/115V, 0.28A/230VAC | ||||
| Impulse Current | Cold Start: 25A/230VAC | ||||
| Leakage Current | <2mA/240VAC | ||||
| Protection | Overload | 110%~150% Rated Output Power, Hiccup Mode, Auto Recovery After Fault Removed | |||
| Environment | Operating Temperature | -20°C~+60°C (Refer To Derating Curve) | |||
| Working Humidity | 20~90% RH, No Condensation | ||||
| Storage Temp. & Humidity | -40~+85°C, 10~95% RH | ||||
| Vibration Resistance | 10~500Hz, 3G, 10min/1cycle, X,Y,Z Axis Each 60min | ||||
| Safety and EMC | Safety Regulations | UL60950-1, TUV EN60950-1 Certified, IP67 | |||
| Pressure Resistance | O/P-FG:0.5KVAC; I/P-O/P:1.5KVAC; I/P-FG:1.5KVAC | ||||
| Insulation Impedance | I/P-O/P, I/P-FG, O/P-FG >100MΩ / 500VDC / 25°C / 70%RH | ||||
| EMC Emissions | Complies With EN55022 Class A | ||||
| Others | Size | 182×30×20mm | |||